TECHNICAL SUPPORT · MAINTENANCE
How to use the
ST2 sterilizing cartridge
Follow the steps to prepare, install and use the reusable ST2 cartridge, then rinse your watermaker before putting it back into service.
USER GUIDE · 9 STEPS
Prepare the watermaker.
Rinse the circuit
With the watermaker off, set the three-way valve to rinse and turn the pressure regulator fully counterclockwise. After 5 minutes, close the valve to shut off the water supply.

Prepare the cartridge.
Open the cartridge
Remove the lid and the upper plastic grille.
Check the foam pad
Make sure the foam pad sits at the bottom of the cartridge.
Add the powder
Pour the sterilizing powder directly onto the foam pad.
Refit the grille
Put the upper grille back in place.
Close the cartridge
Turn the lid over before refitting it so the white seal faces outwards.
Install and activate the cartridge.
Install the cartridge
Remove the 5-micron filter from the prefilter bowl and replace it with the ST2 cartridge. The PDF shows the installation for Freedom, Cruise and DUO models, and for Compact and CAD models.
Close the prefilter bowl
Check that the O-ring at the top of the bowl is seated correctly, then close the bowl.
Let fresh water flow
Set the three-way valve to fresh water. Let the bowl fill and the powder dissolve, leaving a little powder on the pad. Return the valve to the closed position.
RINSING REMINDERS
After sterilization.
Rinse the membranes.
Set the valve to fresh water for 5 minutes to flush out excess sterilizing agent, then close it.
Prepare to restart.
Rinse with fresh water for 15 minutes and close the valve. Replace the cartridge with a new 5-micron filter. Set the valve to fresh water to refill the prefilter and purge air. Once the prefilter is full and the air is out, set the valve back to seawater.
True quality is built to last!